System Outages Sample Clauses
POPULAR SAMPLE Copied 4 times
System Outages. Each Party shall use its best efforts to avoid unscheduled System Outages in the performance of each Party's respective rights and obligations under this Agreement.
System Outages a. CONSULTANT shall review and evaluate the CONTRACTOR’s system outage requests (SOR) in conjunction with the CITY. CONSULTANT shall assess the reasonableness of the duration of the requested shutdown.
b. The SORs shall be reviewed and approved at least two weeks ahead of the actual outage/shutdown.
c. CONSULTANT shall facilitate/coordinate shutdowns with the CONTRACTOR, CITY and ENGINEER.
i. CITY is responsible for reviewing and approving system outage request and duration, confirming the outage is properly planned, implementing the outage, and bringing services back online after the outage.
System Outages. In the event of unavailability of systems, e.g. Prequel, the Coverholder will temporarily cease activities insofar as data is required. If system outages persist and outputs from the service are required, activities may be performed from the most recent backup of data, or previous year product strategy documents can be used, whichever is deemed to provide a more accurate view by the Underwriter.
System Outages. Work, which requires any existing building utility system (including fire protection) to be taken out of service, shall be scheduled and performed so that the length of time the utility is out of service is held to a minimum. All material for the alteration and tie-in work shall be on hand when each utility service interruption is scheduled. The Contractor shall notify Battelle not less than five (5) working days prior to each required utility shutdown. All tie-in work shall be scheduled and performed so that the shutdown time will not exceed four (4) hours for water and two (2) hours for electrical or fire alarm. Battelle shall approve methods of performing the tie-in work prior to any utility system outage. Prior approval must be obtained for connection to and use of existing fire hydrants.
System Outages. In the event of unavailability of systems, e.g. Oracle, Anaplan, Prequel, the Coverholder will use best efforts and alternative data sources (such as back-ups or an alternative system than is typically used) to produce collateral management reporting using a working paper process. The Coverholder will enter the data maintained off-system during the outage into the relevant system within one week of the system outage event occurring.
System Outages. In the event of unavailability of systems, e.g. FireAnt, the Coverholder will temporarily cease activities insofar as data from these systems is required. The Coverholder will continue to operate other aspects of the management reporting process on a best-efforts basis, using EUC solutions. If system outages persist and outputs from the service are required (e.g. past quarter close), the Coverholder will make commercially reasonable efforts to produce required information, using the most recent backed-up data rolled forward to the reporting date.
System Outages. In the event of unavailability of systems, e.g. Prequel, Oracle, the Coverholder will continue to match cash balances using templates maintained in EUC solutions and bank records. The Coverholder will enter the data maintained off-system during the outage into the relevant system within one month of the service being restored.
System Outages. In the event of unavailability of systems, e.g. Oracle, Anaplan, the Coverholder will temporarily cease activities insofar as data from these systems is required. The Coverholder will continue to operate other aspects of the annual planning process on a best-efforts basis. If system outages persist and outputs from the service are required, the Underwriter may instruct the Coverholder to either: ● Prepare an annual plan using Excel ● Operate using the prior-year’s annual plan, adjusted for known events ● Prepare an updated plan on the basis of the most recently available back-up data, adjusted for known events
System Outages. In the event of unavailability of systems, e.g. the DUA tool, the Coverholder will temporarily cease activities insofar as access to these systems required. The Coverholder will continue to operate other aspects of the service on a best-efforts basis, using EUC solutions. The Coverholder will enter the data maintained off-system during the outage into the relevant system within one month of the system outage event occurring.
System Outages. (a) Pricing In the event of unavailability of systems, e.g. FireAnt, the Coverholder will continue to underwrite business insofar as is possible without system support using manual processes.
(b) Capital management and reserving In the event of unavailability of systems, e.g. FireAnt, Tyche, the Coverholder will temporarily cease activities insofar as data from these systems is required. The Coverholder will continue to operate other aspects of these processes on a best-efforts basis, using EUC solutions. If system outages persist and outputs from the service are expected to be required before the service is restored (e.g. past quarter close), the Coverholder will produce the required actuarial information at the most recently available reporting date, and begin work to meet the existing deadline as soon as practical. The Underwriter will then perform an assumption-based roll-forward exercise to the reporting date.